About this product
Mattress TypeAir Mattress
Mattress FeelMedium
Bedding SizeSingle
Supported Weight(kg)Above 25 kg
Quantity per Pack1
Product description
The scope of application:
This product is suitable for bedridden patients, to prevent patients from acne due to long-term bed.
The product structure consists of:
This product is composed of inflatable cushion and air pump. The inflatable cushion is made of high frequency heat-sealable PVC cloth. It has a spherical air chamber. The air pump is connected to the inflatable cushion through joints, air pipes, air inlets, etc. Inflate the air chamber.
Through the inflator pump, the odd and even air chambers of the inflatable cushion are alternately filled and deflated, so that the patient's body bed part is in intermittent contact with the cushion surface to achieve an anti-acne effect. When the inflation pressure reaches 3 kPa, the cushioned micro-jet holes are evenly distributed. Emissions of gases outside the body improve air circulation under the body of the patient and enhance anti-acne effects.
The main technical indicators:
1, when filling and deflation: single pump air pump inflation 5min ยฑ 5%, deflation 5min ยฑ 5%, dual pump air pump 9min ยฑ 5%, deflation 9min ยฑ 5%;
2. Inflatable air pressure: 12kPa ยฑ 0.5kPa (can be adjusted between 0 and maximum air pressure);
3, the most weight bearing: 135kg;
5, continuous working time: >24h
6. Inflatable pump power consumption:
1, bad environment temperature: 5-40 ยฐC;
3, power conditions: 220V ยฑ 22V, 50hz
1. Place the air mattress on the sickbed or single bed (the surface of the bed surface cannot be pointed or hard to prevent the air cushion from being damaged) so that the air intake hole is located on the patient's foot;
2. Take the air pump out of the foam box, according to the situation, it can be placed on the desktop or under the bed with a solid position more than 20cm above the ground, and the use environment should be clean and dry;
3. Turn on the air pump power, turn on the power switch, and turn the pressure adjusting knob clockwise to the maximum state. The air outlet of the air pump has gas discharge, which is suitable for single pump air pump;
4. Connect one end of the airway tube to the air nozzle on the mattress, and connect the other end to the air outlet on the right side of the air pump. The connection should be firmly in place and no air leakage can occur.
5. The air mattress enters into the inflation work state. After inflating for 15-20 minutes, the pressure in the air bed can reach the normal state of use. If necessary, a bed sheet can be laid on the air mattress and the patient can be moved to the air cushion according to the needs of the patient. Adjust the air pump pressure adjustment knob to change the softness of the air heat;
6. Unfasten the snaps on both sides when you are in urine and excretion, and open the small air cushion at the hole. Then you can use it conveniently. Then return to the original position to restore the fluctuating state.
7, according to the needs