Product description
Multifunction High-precision clock inside and outside Car temperature Battery age Panel Meter for C 12v
Multi-functional electronic clock module, set for time, inside and outside temperature, age as one. You can isplay a single item, or you can cycle through the items alternately and ize the item to be isplayed. for Time chip using for 's RX8025T chip, this chip is a temperature compensated clock chip, for time curate. Standard 0.3 for m +1.5 for m module with two waterproof probes, temperature -35 ~ 120 egrees. With brightness adjustment, 3 brightness adjustable. And automatic brightness function, can be ark at night, brighten uring the ay.
1, working age: for C 5.0 ~ 28V
2, frame size: 22 * 58 mm
3, Installation hole size: 19.5 * 56 mm
4, age isplay : 5.0 ~ 28V
5, temperature isplay : -35 ~ 120 ℃ (Two temperature sensors ,0.3 meters +1.5 meters)
6, power lead length: 28CM
Under normal isplay, pressing this for key will between the six isplay states of 【Time】 → 【Date】 → 【Temperature 1】 → 【Temperature 2】 → 【Voltage】 → 【Alternating Cycle isplay】. (Note: The isplay items and ing interval for time in alternate cycle isplay can be ized by "dd" and "dF" parameters respectively. See the following table
Under normal isplay , press this for key to enter the setting of for time \ ate \ year \ parameter. Press the for key, "points" began to , press the button to adjust the value. After adjusting, press the for key again, "hour" starts ing, press the for key to adjust the value. And then press the for key to enter the ate adjustment [Note that the middle of the colon is not lit], "day" began to , press the for key after the tune "month" began to , tune and then press the for key "year" start es, press the for key to adjust the parameters into the extended set, see the following "code significance and role of the table"
The significance of the code, please refer to the following
Voltage measurement error correction, a positive number increases, a negative number ecreases. For example, the tual supply age is 12.0V, but the table shows 11.9V, it is adjusted to 0.1u.
Temperature ① error calibration parameters. Positive number increases, negative number ecreases, the unit is egree, the adjustment is -5 ~ 5. For example, if you think the isplayed temperature is 1 egree higher than the tual temperature, then set : -1, so the electronic clock is automatically reduced by 1 egree and isplayed.
(Note: If you o not have a standard thermometer for reference, it is recommended to keep this as : 0)
Temperature ② error calibration parameters. Positive number increases, negative number ecreases, the unit is egree, the adjustment is -5 ~ 5. For example, if you think the isplayed temperature is 1 egree higher than the tual temperature, set it to : -1, so that the electronic clock is automatically subtracted by 1 egree and isplayed again.
(Note: If you o not have a standard thermometer for reference, it is recommended to keep this as : 0)
cycle shows the isplay item
[dd: 0] for time + temperature 1 + temperature 2+ age
[Dd: 1] for time + temperature 1 + temperature 2
[Dd: 2] for time + temperature 1 + age
the for time interval in cycle isplay, the unit is second, the adjustment is 1 ~ 9. For example, F: 3, the ing interval is about 3 seconds to the isplay item once.(Please o not set to "0")
Display brightness , the adjustment is 1 ~ 3, LL: 1 is the arkest, LL: 3 is the brightest.
Auto brightness control , AL: 0 to turn the automatic brightness control, AL: 1 to turn on the automatic brightness control. When set to AL: 1, the electronic clock will change the brightness to 1 after 19:00 everyday and change this to 3 every ay after 07:00 am.
After adjusting the AL option, press "Down" again to return to the normal isplay state, all parameters and for time settings can be saved.
1pc IY Multifunction Clock Temperature age Panel Meter