Product description
Wide Voltage Power Supply 5. 0v--60v;
You Can Set More than One Time Periods in One Mode, up to 5 One Time Periods;
With Buzzer Alarm Function.
OPE: Relay Closing Time CLE: Relay Disconnection Time
Time Period: PE-1 to PE-5,5 One Time Period
P-1: Daily Ope Relay Closed/Output Pulse CLE Relay Open/Output Pulse
P-2: on the Same Day, the OPE Relay Is Closed/the Output Pulse CLE Relay Is Disconnected/the Output Pulse
P-3: What Day Is the Date: Ope Relay Closed/Output Pulse CLE Relay Open/Output Pulse
P-4: from the Date of the Month to the Date of the Month, What Time Does It Start Every Day and End by What Time: Ope Relay Closed/Output Pulse CLE Relay Open/Output Pulse
P-5: What Day to What Day of Each Month Start and End: Ope Relay Closed/Output Pulse CLE Relay Open/Output Pulse
Note: Stop Time/Date (CLE)> Start Time/Date (OPE)
First, How to Set the Time
On the Time Runtime Page, Press down:
1. after the System Blinks and Displays "Yea", Enter the Time Setting Interface. at This Time, the Two Digits of "Year" Blinks and Are Adjusted by down and up (Long Press Is Supported);
2. after the "Dae" Is Displayed in the Short Press Set System, Enter the "Month/Day" Setting Interface. at This Time, the "Month" Keeps Flashing and Is Adjusted by down and up (Long Press Is Supported);
3. Press Set in a Short Time. at This Time, the "Day" Flashes and Is Adjusted by down and up (Long Press Is Supported);
4. Press Set in a Short Time. after the System Flashes and Displays 'Hou', Enter the "Hour/Minute" Setting Interface. at This Time, the "Hour" Keeps Flashing and Is Adjusted by down and up (Long Press Is Supported);
5. Press Set in Short. at This Time, the "Minute" Flashes. Adjust by down and up (Long Press Is Supported). at This Time, Press Set in Short. Repeat Step 1;
6. after You Press Set for a Long Time, You Will Modify the Time According to the Set Parameters and Exit the Time Setting Interface;
Second, How to Set Parameters
In the Time Running Interface, Press the Set Key for 2 Seconds and Then Let Go. the System Enters the Parameter Setting Interface:
Step: Select a Time Period: PE-1 to PE-5. Press the up and down Keys to Select the Time Period;
Step 2: Select the Mode: "----" P-1 ~ P-5 (That Is, Set This Time Period to the Corresponding Mode) by Short Pressing the up and down Keys; (---- Indicates Blocking This Time Period)
The Repeat Mode of Each Time Period Can Be Selected from ----, P-1 to P-5. for Example, You Can Make 5 One Time Periods Work in P-1 Mode at the Same Time, or Let Time Period 1 Work in P-1 Mode, Time Period 2 Work in P-2 Mode, Etc.; Very Convenient and Flexible, Can Be Combined According to Your Own Needs;
Step 3: After the Mode Is Selected, Press Set to Enter the Time Period Setting Interface. on the Time Period Setting Interface, Switch the Parameters by Pressing Set to Start the Time Point of "Ope," Cle "End Time Point," Dae "Date Information;
Step 4: Exit the Setting after the Parameter Setting Is Completed. Press the Set Key for 2 Seconds and Then Release It to Check Whether the Parameter Setting Is Legal. If It Is Legal, Save the Parameter and Return to the Time Running Interface; if the Parameter Is Incorrect, the "Err" Reminder Is Displayed (Stop Time/Date <= Start Time/Date, Error Is Reported) and Returns to the Parameter Setting Interface Again;
Note: Stop Time/Date (CLE)> Start Time/Date (OPE)
Additional Features: Can Be Set Separately for Any Time Period
In the Specific Parameter Setting Interface (after Step 2), Press Stop to Switch the Output Mode:
Out1: Start Point Conduction Relay, End Point Disconnect Relay
Out2: Output 1S Pulse at the Time Point
On the Parameter Setting Page (after Step 2), Press Stop for a Long Time to Switch to Answer Ring Pattern:
Note: After Ringing, Press Any Button to Stop the Ringing.
Stop Button Feature Extensions:
1. on: Relay Conduction Within the Relay Conduction Time;
2. off: The Relay Is Forbidden to Conduct and Is Always Closed;
Press Stop Button in the Time Display Interface to Switch between on and off. The Current Status Will Flash and Then Return to the Main Interface. (This Function Is the Emergency Stop Function, One Key to Disconnect the Closed Relay)
After the Relay Is Disabled, It Will Be the Alarm Clock Function after the Mode Is Set.
1. C- P Sleep Mode: Within Five Minutes, There Is No Operation, Digital Tube Automatically Closes the Display, and the Program Runs Normally;
2. O-d Normal Mode: Digital Tube Always Turn on Display;
On the Time Display Interface, Press Stop Button for 2 Seconds and Then Release It to Switch between C- P and O-d States. The Current State Will Flash and Then Return to the Main Interface.