TikTok Shop Singapore logo
Search
1/5
S$9.28
S$11.60-20%

Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen

Sold by KIN-SG

Select options

Select

Shipping

From S$1.49
Est. delivery by Apr 23 - Apr 26
KIN-SG
1,360 items

Product description

Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 0
1. Heating Mode 'H ':
When the Detection Temperature Is Less than Or Equal to the Set Temperature-Return Temperature, the Relay Is Turned on and Starts to Work on Heating Equipment;
When the Detection Temperature Is Greater than Or Equal to the Set Temperature, the Relay Is Disconnected and Heating Equipment Stops Working;
2. Cooling Mode 'C ':
When the Detection Temperature Is Greater than Or Equal to the Set Temperature + Return Temperature, the Relay Is Turned on and the Refrigeration Equipment Starts to Work;
When the Detection Temperature ≤ the Set Temperature, the Relay Is Disconnected and the Refrigeration Equipment Stops Working;
3. High Temperature Alarm Function Ala:
When the Actual Temperature Is Greater than Or Equal to the Alarm Temperature, the System Turns on the Sound and Light Alarm, Disconnects the Relay, and Stops the Sound and Light with Any Key;
4. Delayed Start Oph:
After a Normal Heating Or Cooling Work Is Completed, the System Starts Timing T. Only When T ≥ Oph Can the System Perform the next round of Heating Or Cooling Work;
5. Temperature Correction Function OFE(-10.0~10.0 ℃):
If the System Works for a Long Time, Deviation May Occur. through This Function, the Actual Temperature = Measured Temperature + Calibration Value;
6. Remote Reading/Setting of Parameters:
You Can Use UART to Set Parameters Such as Start Temperature, Stop Temperature, and Temperature Correction;
7. Real-Time Temperature Reporting:
If the Temperature Reporting Function Is Enabled, the Product Transmits the Detected Temperature to the Terminal through UART at 1S Intervals for Data Collection;
8. Relay Enable (Enabled by Default):
If the Relay Is Enabled, the Relay Remains Disconnected;
9. Restore Factory Settings:
Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 20
Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 21
Working Mode/Set Temperature/Return Temperature Setting:
1. in the Running Interface, Press the Set Key to Enter the Quick Setting Interface;
2. after Entering the Quick Setting Interface, Switch the Parameters to Be Set by Short Pressing the Set Key (Working Mode/Setting Temperature/Return Temperature);
3. Use the up down Key to Modify the Parameter Value. Short Press/Long Press Are Supported;
4. Press Set to Create More than 3S Or Continue for 6S without Any Button Operation. Exit the Quick Settings Interface and Save the Parameters;
Alarm Temperature/Delay Start Setting/Temperature Correction:
1. in the Operation Interface, Press Set to Build More than 3S to Enter the Parameter Setting Interface;
2. after Entering the Parameter Setting Interface, Switch the Parameters to Be Set by Short Pressing the Set Key (Alarm Temperature/Delay Start Setting/Temperature Correction);
3. Use the up down Key to Modify the Parameter Value. Short Press/Long Press Are Supported;
4. Press Set to Create More than 3S Or Continue for 6S without Any Button Operation. Exit the Parameter Setting Interface and Save the Parameters;
How to Enable High Temperature Alarm (Disabled by Default):
Enter the Parameter Setting Interface, Switch to the Alarm Parameter Ala Interface, and Turn on Or off the High Temperature Alarm Function by Short Pressing the Stop Key; If the High Temperature Alarm Function Is Turned off, ALA Displays '----' as a Reminder;
How to Enable Delayed Startup (Disabled by Default):
Enter the Parameter Setting Interface, Switch to the Alarm Parameter Oph Interface, and Turn on Or off the High Temperature Alarm Function by Short Pressing the Stop Key; If the High Temperature Alarm Function Is Turned off, Oph Displays '----' as a Reminder;
Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 36
Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 37
Product Introduction of Electronic Modules Digital Thermostat Digital Display Temperature Controller Module Refrigeration Heating Control Module XY-T01 with Display Screen 38
Serial Port Control
(TTL Level Communication of Single Chip Microcomputer)
Communication Standard: 9600bps Data Bit: 8 Stop Bit: 1 Check Bit: None Flow Control: None
Serial Command
Description
start
Start Temperature Reporting
stop
Stop Temperature Reporting
read
Read Setting Parameters
on
Relay Enable Opening
off
Relay Enable Shutdown
S:XXX
Set the Set Temperature
-50 ~ -01
B:XX.X
Set the Return Temperature (00.0~30.0)
OFE:XX.X
Temperature Correction (-10.0 to 10.0)
ALA:XX.X
Alarm Temperature (-50.0 ~ 110.0)
OPH:XXXX
Delayed Start Time (0 to 9999)
You may also like
Womenswear & Underwear
Phones & Electronics
Fashion Accessories
Menswear & Underwear
Home Supplies
Beauty & Personal Care
Shoes
Sports & Outdoor
Luggage & Bags
Toys & Hobbies
No more products
TikTok Shop promo codes
Sell on TikTok ShopSeller center
About TikTok ShopContact usCareersAffiliate
Help centerSafety centerCommunity guidelines
TransparencyAccessibility
Open TikTok