Product Description:
New high quality
Made of high quality material and
Charging mode IN
By setting the upper limit voltage UP and the lower limit voltage dn; When the battery voltage is less than the lower limit voltage dn, the relay is switched on and the charger starts to charge the battery. When the battery voltage is not less than the upper limit voltage UP, the relay is disconnected and an automatic charge is completed. The relay is on and blinking IN indicates that it is being charged.
Discharge mode OUT
By setting the upper limit voltage UP and the lower limit voltage dn; When the battery voltage is greater than or equal to the upper limit voltage UP, the relay switches on and starts discharging. When the battery voltage is less than or equal to the lower limit voltage dn, the relay is disconnected to complete an automatic discharge function; The relay is on and blinking OUT indicates that it is discharging.
Note: This product is a simple voltage controller, which is used to turn on and off the output through the relay. It only plays the role of switching, but cannot change the voltage.
Function description:
1. Calculation of voltage percentage: battery voltage/(upper voltage - lower voltage)
2. Key function:
UP button: Short press to switch the display % and time, long press for 5 seconds to switch modes, charging mode: IN, discharge mode: OUT
SET key: Short press to view the current set parameters; Long press the SET button to enter the parameter setting interface, and set UP: upper voltage limit, dn: lower voltage limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: strong guidance turn-on time (0-10 seconds) in discharge mode.
DOWN button: Press the button to turn OFF/on the relay ( stop function). After closing, the LCD will be off and the relay will be disconnected
Long press the DOWN button to set the state of the LCD backlight L-P:OFF the backlight is always ON, ON: the backlight will be automatically extinguished after 5-10 minutes; Any button to for wake up after extinguishing.
3. Set parameters
a. Hold down the SET key to enter the parameter setting screen.
b. On the parameter setting screen, press the SET key to switch to the set parameters.
c. After selecting the parameters, you can use the UP/DOWN keys to set the parameters. You can press or hold down the parameters.
d. To set other parameters, repeat steps b), c);
e. After all parameters are SET, long press the Set key to exit and save;
3.1 Charge/discharge time control function
When the time parameter OP is set to non-zero, start the charge/discharge time control; When the relay conduction starts a charge/discharge, the timing begins; When the timing is complete, the relay is automatically disconnected to complete a charge/discharge process; If the timing is complete, in charging mode, the detection voltage is < lower limit voltage dn or in discharge mode, the detection voltage is > upper limit voltage UP, the charging time control function is automatically closed, and H:ER flashes to remind the user that the time parameter setting is unreasonable. Press any key to stop flashing;
When the charging/discharging time control is not enabled, the product will record a complete time. When entering the time display interface, the charging time will be displayed blinking; Then exit the time display interface or open the next charge (relay conduction) empty;
3.2 Automatic parameter detection:
When the parameters are set and exit, if the lower limit dn is greater than the upper limit DN is up, the displays ERR to remind you.
3.3 Delay Switch Function dOP(0-999 seconds):
The interval between completion of a charge/discharge and re-opening;
3.4 Forced-start time FOP(0~10S):
After the relay turn-on condition is satisfied, the relay is strongly guided to turn on (0~10S), and the battery voltage is detected again. This function is mainly aimed at discharge function. Some test loads will pull down to the lower limit voltage instantaneously at the moment of switching, and the wrong trigger will to the disconnection of the relay and the normal discharge process cannot be carried out.
The package includes:
1 * automatic off switch module
Note:
1.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2.Please allow slight manual measurement deviation for the data.