Product description
● Rated current(ln): 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
●Rated residual working current: 30mA(standard default)
□ Over-current fault: the circuit breaker and the residual current operating device are reset at the same time
□ Leakage fault: reset the residual current operating device first, then reset the circuit breaker
□ protection failure: the protection device is reset first, and the circuit breaker is reset later
● Number of poles: 2P(single-pole two-wire residual current operated circuit breaker)
● Trip type: Type C(5~10) In(standard default) and Type D(10-16) ln( for customized)
● Rated voltage Un(v): AC 220V-250V, 110V-127V( for customized)
● Rated isolation voltage: 500V● protection level: 3
● Rated short-circuit capacity Lcb(A): 6kA
● Insulation impulse voltage: 8KV
: Power input and output terminals(up to 16mm2(5 AWG) cables can be connected).
2: PE port terminal grounding wire can be connected
3: Status window, red means power is on, green means power is off(circuit breaker tripped).
4: Manual opening and closing handle: turn up to turn on the power, turn down to turn off the power.
5: Test button, turn on the power and press this button to test whether the leakage protection function is good:
If the circuit breaker trips, the leakage protection function is good;
If the circuit breaker does not trip, there is a problem with the leakage protection function. Please replace the circuit breaker in time.
8: Leakage protection indication reset button, please press this button before power is restored