House Alarm TypeHome Security System
Alarm Volume95dB
Product description
NOTES:When the CO detector value reaches 300PPM or above, the detector will sound an alarm
Preheating status: once powered on, the detector will enter working status after 100s countdown.
Monitoring status: the green indicator flashes once every 60s.
Self-checking status: in normal status, press and hold the self-check/mute button on the side of the housing for ís, detector will sound the alarm, the red/green/yellow indicators will turn ON simultaneously, and the screen will display 888. Self-checking is recommended to be done on a weekly basis. lf you press the self-check/mute button but the detector does not work normally,contact your supplier for repair in time.
Alarm status: when the detector detects CO gas in a certain concentration, the red indicator will flash,current concentration value will display when gas concentration exceeds the preset alarm activation value, the red indicator will flash, buzzer will beep and current concentration value will display.
eFault status: the yellow indicator flashes, and the buzzer beeps at the same time.
Low voltage status: the yellow indicator flashes, Lo instantly displays, this process cycles once every 60s.
In alarm status, press and hold the self-check/mute button on the side of the housing for 1s.